CLOSE
FREE SHIPPING
ON ORDERS OVER $59*
DOMESTIC, UNDER 10 LBS
Home  >  Shop by Brand  >  Accu-Chek  >  Accu-ChekŪ Guide Blood Glucose Monitoring System
UPC: 0365702702035
Code: accu-chek-guide-glucose-monitor

Accu-ChekŪ Guide Blood Glucose Monitoring System

Accu-ChekŪ Guide Blood Glucose Monitoring System
Click To Enlarge


Retail Price: $89.95
Your price: $39.95
You Save: $50.00 (56%)
Qty:
In Stock
Important: Product packaging may differ from picture shown
SAME DAY SHIPPING
HASSLE FREE RETURNS
100% SECURE
  • Description
  • Features
  • Technical Specs
  • Intended Use
  • Safety Information
  • Limitations
  • Warranty
  • More
Accu-Chek Guide Blood Glucose Monitoring System
Accu-ChekŪ Guide Blood Glucose Monitoring System

No coding required meter! Accu-Chek is known for their accuracy and consistency. Quick results! The Accu-Chek Guide features a strip ejector and a port light! So now you have a more sanitary option of disposing your strips and for testing in low light places and situations such as nighttime. It also features a smart phone app that connects your phone and your test results! So no more having to write down notes or worrying about having a pen and paper nearby because now your results go where you go!

Questions: Contact Manufacturer at 800-858-8072

Features

Spill-resistant - and simple to take just one strip

Simple to use - the entire end of the test strip

Anytime - testing with a strip port light

Automatic - logging of results to your smartphone

Accurate - reliable results you can trust

Uses

Intended Use

The Accu?Chek Guide Blood Glucose Monitoring System is intended to quantitatively measure glucose in fresh capillary whole blood from the fingertip, palm, and upper arm as an aid in monitoring the effectiveness of glucose control.

 

The Accu?Chek Guide Blood Glucose Monitoring System is intended for in vitro diagnostic single?patient use by people with diabetes.

 

The Accu?Chek Guide Blood Glucose Monitoring System is intended to be used by a single person and should not be shared. This system is not for use in diagnosis or screening of diabetes mellitus, nor for neonatal use.

Technical

NaN

Warnings

NaN

Other

Limitations

• Do not use the meter at high hematocrit levels above 65 % or low hematocrit levels below 10 %.

• Not for use in diagnosis or screening of diabetes mellitus.

• Not for neonatal use.

• Abnormally high concentrations of ascorbic acid (vitamin C) resulting in blood concentrations in excess of 5 mg/dL may cause inaccurate results. If you are not sure please check with your doctor.

• Do not use the meter system to measure blood glucose in people who are experiencing cardiovascular collapse (severe shock) or decreased peripheral blood flow.

• Do not use this system during xylose absorption test.

• Not for use on critically ill patients, patients in shock, dehydrated patients, or hyperosmolar patients.

• This system has not been tested at altitudes higher than 10,150 feet.

Roche Diabetes Care, Inc.
9115 Hague Road - PO Box 50457 - Indianapolis, IN 46250-0457

Product Reviews

Spill-resistant - and simple to take just one strip



Simple to use - the entire end of the test strip



Anytime - testing with a strip port light



Automatic - logging of results to your smartphone



Accurate - reliable results you can trust

Specifications



Blood volume    Refer to the test strip package insert.



Sample type       Refer to the test strip package insert.



Measuring time                Refer to the test strip package insert.



Measuring range              Refer to the test strip package insert.



Test strip storage conditions       Refer to the test strip package insert.



System operating conditions      Refer to the test strip package insert.



Meter storage conditions             Temperature: ?13–158 °F



Memory capacity             720 blood glucose results and 32 control results with time and date



Automatic off    90 seconds



Power supply    Two 3?volt lithium batteries (coin cell type CR2032)



Display  LCD



Dimensions        80 × 47 × 20 mm (LWH)



Weight Approx. 40 g (with batteries)



Construction      Hand?held



Protection class III



Meter type         The Accu?Chek Guide meter is suitable for continuous operation.



Control solution storage conditions         Refer to the control solution package insert.



Interfaces           USB: micro?B connector; Bluetooth Low Energy;  Continua Certified® to a Continua Certified manager.



Radio frequency connectivity     Bluetooth low energy technology operating in the frequency band of 2402 MHz to 2480 MHz with a maximum transmitted power of 0 dBm (1 mW).

Intended Use



The Accu?Chek Guide Blood Glucose Monitoring System is intended to quantitatively measure glucose in fresh capillary whole blood from the fingertip, palm, and upper arm as an aid in monitoring the effectiveness of glucose control.



 



The Accu?Chek Guide Blood Glucose Monitoring System is intended for in vitro diagnostic single?patient use by people with diabetes.



 



The Accu?Chek Guide Blood Glucose Monitoring System is intended to be used by a single person and should not be shared. This system is not for use in diagnosis or screening of diabetes mellitus, nor for neonatal use.

Safety Information



WARNING



• During normal testing, any blood glucose meter or lancing device may come in contact with blood. All parts of the kit are considered biohazardous and can potentially transmit infectious diseases from bloodborne pathogens, even after you have performed cleaning and disinfecting.



• The meter and lancing device should never be used by more than one person. Do not share the meter and lancing device with anyone, including family members, due to the risk of infection from bloodborne pathogens. Do not use on multiple patients!



• Cleaning and disinfecting the meter and lancing device destroys most, but not necessarily all, bloodborne pathogens.



• If the meter is being operated by a second person who is providing testing assistance to the user, the meter and lancing device should be cleaned and disinfected prior to use by the second person.



• Disinfect the meter and lancing device before allowing anyone else to handle them. Do not allow anyone else to test with the meter or lancing device.



• It is important to keep the meter and lancing device clean and disinfected. For instructions on how to clean and disinfect the meter and lancing device, see the chapter Meter and Lancing Device Cleaning and Disinfecting. • Wash hands thoroughly before and after handling the meter, lancing device, or test strips.

Limitations



• Do not use the meter at high hematocrit levels above 65 % or low hematocrit levels below 10 %.



• Not for use in diagnosis or screening of diabetes mellitus.



• Not for neonatal use.



• Abnormally high concentrations of ascorbic acid (vitamin C) resulting in blood concentrations in excess of 5 mg/dL may cause inaccurate results. If you are not sure please check with your doctor.



• Do not use the meter system to measure blood glucose in people who are experiencing cardiovascular collapse (severe shock) or decreased peripheral blood flow.



• Do not use this system during xylose absorption test.



• Not for use on critically ill patients, patients in shock, dehydrated patients, or hyperosmolar patients.



• This system has not been tested at altitudes higher than 10,150 feet.

Accu?Chek Guide Meter Limited 3?Year Warranty



Roche warrants to the original purchaser of the meter that your Accu?Chek Guide meter will be free from defects in materials and workmanship for three years from the date of purchase. If, during this 3?year period, the meter does not work properly because of a defect in materials or workmanship, Roche will replace it with a new Accu?Chek Guide meter or equivalent product free of charge. The warranty on the replacement meter will expire on the date of the original warranty expiration or 90 days after the shipment of a replacement system, whichever period is longer. The purchaser’s exclusive remedy with respect to the Accu?Chek Guide meter shall be replacement.



 



This warranty does not apply to the performance of an Accu?Chek Guide meter that has been damaged by accident or has been altered, misused, tampered with, or abused in any way. Roche will handle meters that show damage or abuse according to its Non?Warranty Service Policy described on the following page.



 



THE ABOVE WARRANTY IS EXCLUSIVE OF ALL OTHER WARRANTIES, AND ROCHE MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL ROCHE BE LIABLE TO THE PURCHASER OR ANY OTHER PERSON FOR ANY INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES ARISING FROM OR IN ANY WAY CONNECTED WITH THE PURCHASE OR OPERATION OF THE METER OR ITS PARTS. NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IF ANY IS IMPLIED FROM THE SALE OF THE METER, SHALL EXTEND FOR A LONGER DURATION THAN THREE YEARS FROM THE DATE OF PURCHASE.



 



Some states do not allow limitations on how long an implied warranty will last or the exclusion of incidental or consequential damages, so the above limitation and exclusion may not apply to you. This warranty gives you specific legal rights, which vary from state to state.

YOU MAY ALSO LIKE
Shopper Award
otcwholesale.com has a Shopper Approved rating of 4.8/5 based on 1938 ratings and reviews

Transcutaneous Electrical Nerve Stimulation (TENS)

TENS is a non-invasive, drug free method of controlling pain, which uses tiny electrical impulses sent through the skin to nerves in order to modify your pain perception. In most people it is effective in reducing or eliminating the pain.

Electronic Muscle Stimulation (EMS)

EMS works by sending electronic pulses to the muscle(s). This is achieved by sending low frequency electric pulses through muscle tissue causing them to gently contract. In this way the muscles are passively exercised and blood flow is increased

Galvanic Stimulators

Galvanic Stimulators use direct current, which creates an electrical field over the treated area. The positive pad works like ice, causing reduced circulation to the area under the pad. The negative pad works like heat, causing increased circulation.

Interferential

IF sends small comfortable electrical impulses through your skin to work on deeper tissue stimulation. The sensation works to prevent pain signals from reaching the brain.

Infrared

Infrared Light Therapy help the body by delivering specific light waveforms that increase circulation. Increasing circulation helps promote healing, lessen swelling, and helps in reducing pain.

Ultrasound

Portable Ultrasounds give advanced pain relief using sonic stimulation of soft tissue cells. They generate pulsed, high frequency sound waves, which travel deep into the tissue, generating vasodilation. This helps increase blood flow to the treated area.

Russian

Russian stimulation uses medium frequencies to provide stimulation to muscle groups. This is used to reduce muscle spasms as well as for muscle strengthening. This method was created to produce maximal muscle strengthening effects.

Micro Current

Microcurrent Therapy uses extremely small amounts of electrical current (millionths of an amp) to help relieve pain and heal soft tissues of the body. The electrical current used in Microcurrent Therapy is so small that it is rarely felt.