CLOSE
FREE SHIPPING
ON ORDERS OVER $49*
DOMESTIC, UNDER 10 LBS
Home  >  Electrotherapy  >  TENS Electrodes  >  Premium TENS Silver Electrode 4 x 6 in Butterfly, Blue Mesh Backed - 1 Pad
UPC: 013964594133
Code: leadlok-20011

Premium TENS Silver Electrode 4 x 6 in Butterfly, Blue Mesh Backed - 1 Pad

Premium TENS Silver Electrode 4 x 6 in Butterfly, Blue Mesh Backed - 1 Pad
Click To Enlarge
Save on Wholesale Discount Pricing
You BuyYour PriceYou SaveTotal Cost
3 or more
6 or more
12 or more
$4.44
$3.93
$3.49
$4.55 (51%)
$5.06 (56%)
$5.50 (61%)
$13.32
$23.58
$41.88
Retail Price: $8.99
Your price: $4.95
You Save: $4.04 (45%)
Recommended Items
Electrode Stimulation Care Kit - Skin Prep, Conductive Spray & Lotion
Electrode Stimulation Care Kit - Skin Prep, Conductive Spray & Lotion
Our Price: $11.95
TENS Unit Replacement Lead Wires with Pin Connectors, 45 in - 2 ea
TENS Unit Replacement Lead Wires with Pin Connectors, 45 in - 2 ea
Our Price: $4.95
Qty:
In Stock
SAME DAY SHIPPING
HASSLE FREE RETURNS
100% SECURE
PRODUCT VIDEO


  • Description
  • Features
  • Directions
  • Warnings
  • Other
  • More
Discover the Lead-lok advantage: Silver Electrodes give you the best performance for all TENS Unit & Muscle Stimulator Electrotherapy applications. These TENS electrodes feature a silver-coated pure carbon pad and copper lug contact for dramatically better charge distribution and delivery, durable backing, American-made multi-use gel, and molded pin-style connectors.
TENS Silver Electrode 4x6" Butterfly, Blue Mesh Backed
Blue Mesh Silver TENS Electrode pad with Multistick Gel for Maximum Reusability

You simply cannot buy a better TENS Unit Electrode!

"Prewired" Reusable Self-Adhering Electrodes For Electro Stimulation

  • Superior silver-coated electrodes deliver more current with better distribution across the entire pad.
  • Molded wire connector for reliability and durability.
  • Flexible solid-carbon pad for maximum charge delivery and comfort.
  • Blue Cloth-Mesh backing for comfort and durability.
  • US made high-stick Ludlow Gel for up to 15-20 uses.



Questions: Call Manufacturer at 1-800-201-3958 or Visit: www.leadlok.com

 

Features:

Shown here are the results of a Dispersion Meter Test

An electrical current is passed through each electrode for a period of 60 seconds. The electrical voltage output is identical for each electrode. The shaded area shows the current being dispersed through the electrodes. Because of Lead-Lok's unique manufacturing process, these electrodes are able to fully disperse the electrical current across the entire surface of the electrode.



We also use copper lead wires with special heads that help promote greater dispersion and prevent wire pull out. Finally, we use only the finest gel on the market today for greater reusability and superior performance. You simply cannot buy a better TENS Unit Electrode!

Directions:

  • Electrodes do not stick well if any lotion, oil, make-up, dirt, ect., is left on skin. Wash treatment areas with soap and water. Rinse thoroughly. Dry completely.
  • Connect stimulator cables securely to the electrodes so no metal is visible.
  • When removing electrodes from liner or skin, lift on corner gently and pull. DO NOT pull by the cables. Doing so may damage electrodes.
  • Adhesive increases when electrodes reach skin temperature. To increase adhesion further, apply small amount of water and air dry couple of seconds. If electrodes are extremely dry or to decrease adhesion, use more water and let air dry for a couple of hours.
  • Adjust stimulator off BEFORE attempting to remove electrodes from skin.

Warnings:

  • Single patient use only.
  • DO NOT apply to broken skin.
  • Should a skin rash occur, immediately discontinue use and contact your clinician.
  • DO NOT stimulate while driving or operating machinery.
  • DO NOT exceed 0.1 watts.

Other Information:

Gel Maintenance

Clean gel surface after each use by holding under dripping water for 5-10 seconds, while gently rubbing gel surface with fingertips.

  1. After cleaning, return electrodes to the liner and store in package at room temperature.
  2. Electrode longevity varies, depending on maintenance, skin condition, frequency of uses, type and site of stimulation. Effective adhesion may be extended by careful cleaning and storing.

Biomedical Innovations
500 Airport Way.
Sandpoint, Idaho 83864
©2014 Lead-Lok www.leadlok.com

Product Reviews

Features:

Shown here are the results of a Dispersion Meter Test

An electrical current is passed through each electrode for a period of 60 seconds. The electrical voltage output is identical for each electrode. The shaded area shows the current being dispersed through the electrodes. Because of Lead-Lok's unique manufacturing process, these electrodes are able to fully disperse the electrical current across the entire surface of the electrode.



We also use copper lead wires with special heads that help promote greater dispersion and prevent wire pull out. Finally, we use only the finest gel on the market today for greater reusability and superior performance. You simply cannot buy a better TENS Unit Electrode!

Directions:

  • Electrodes do not stick well if any lotion, oil, make-up, dirt, ect., is left on skin. Wash treatment areas with soap and water. Rinse thoroughly. Dry completely.
  • Connect stimulator cables securely to the electrodes so no metal is visible.
  • When removing electrodes from liner or skin, lift on corner gently and pull. DO NOT pull by the cables. Doing so may damage electrodes.
  • Adhesive increases when electrodes reach skin temperature. To increase adhesion further, apply small amount of water and air dry couple of seconds. If electrodes are extremely dry or to decrease adhesion, use more water and let air dry for a couple of hours.
  • Adjust stimulator off BEFORE attempting to remove electrodes from skin.

Warnings:

  • Single patient use only.
  • DO NOT apply to broken skin.
  • Should a skin rash occur, immediately discontinue use and contact your clinician.
  • DO NOT stimulate while driving or operating machinery.
  • DO NOT exceed 0.1 watts.

Other Information:

Gel Maintenance

Clean gel surface after each use by holding under dripping water for 5-10 seconds, while gently rubbing gel surface with fingertips.

  1. After cleaning, return electrodes to the liner and store in package at room temperature.
  2. Electrode longevity varies, depending on maintenance, skin condition, frequency of uses, type and site of stimulation. Effective adhesion may be extended by careful cleaning and storing.
YOU MAY ALSO LIKE
Shopper Award
otcwholesale.com has a Shopper Approved rating of 4.8/5 based on 1938 ratings and reviews

Transcutaneous Electrical Nerve Stimulation (TENS)

TENS is a non-invasive, drug free method of controlling pain, which uses tiny electrical impulses sent through the skin to nerves in order to modify your pain perception. In most people it is effective in reducing or eliminating the pain.

Electronic Muscle Stimulation (EMS)

EMS works by sending electronic pulses to the muscle(s). This is achieved by sending low frequency electric pulses through muscle tissue causing them to gently contract. In this way the muscles are passively exercised and blood flow is increased

Galvanic Stimulators

Galvanic Stimulators use direct current, which creates an electrical field over the treated area. The positive pad works like ice, causing reduced circulation to the area under the pad. The negative pad works like heat, causing increased circulation.

Interferential

IF sends small comfortable electrical impulses through your skin to work on deeper tissue stimulation. The sensation works to prevent pain signals from reaching the brain.

Infrared

Infrared Light Therapy help the body by delivering specific light waveforms that increase circulation. Increasing circulation helps promote healing, lessen swelling, and helps in reducing pain.

Ultrasound

Portable Ultrasounds give advanced pain relief using sonic stimulation of soft tissue cells. They generate pulsed, high frequency sound waves, which travel deep into the tissue, generating vasodilation. This helps increase blood flow to the treated area.

Russian

Russian stimulation uses medium frequencies to provide stimulation to muscle groups. This is used to reduce muscle spasms as well as for muscle strengthening. This method was created to produce maximal muscle strengthening effects.

Micro Current

Microcurrent Therapy uses extremely small amounts of electrical current (millionths of an amp) to help relieve pain and heal soft tissues of the body. The electrical current used in Microcurrent Therapy is so small that it is rarely felt.