This professional device is unique... it comes standard with 2 sound heads,
1 cm and 5 cm, that are both plugged into the device at the same time. Package also includes Starter Kit

Current Solutions Sound Care Plus - Professional Ultrasound with 2 heads plus Starter Kit
Advance pain relief using sonic stimulation of soft tissue cells

The SoundCare™ Plus is the newest addition to the Current Solutions™ line of innovative products. The SoundCare Plus™ is a Professional Ultrasound device, designed by Clinicians. This professional device is unique... it comes standard with 2 sound heads, 1 cm and 5 cm, that are both plugged into the device at the same time. The user can switch between wands with a single button push. The SoundCare™ Plus has 20 presets and operates in 1 MHz and 3 MHz frequencies.

Questions: Contact Current Solutions: 1-800-871-7858 or Visit: www.CurrentSolutionsNow.com

 

Package Includes:

Directions:

1. Connect power wire to wire socket.
2. Connect AC adaptor to power.
3. Apply sufficient gel to skin at target area.
4. Switch on the power. It power signal light is on, start to use Portable Ultrasound.
5. Place the treatment head on the skin and move it slowly over the target area in a circular motion or in linear strokes at a rate of about 1 inch per second. DO NOT stop moving treatment head while in use.
6. Use special care on bony prominence's to avoid discomfort.
7. The power automatically turns off in 10 minutes or, if desired, the power can be turned off sooner by pushing the ON/OFF switch to OFF.
8. After using the Sound Care Plus, clean skin with water to remove gel.
9. Wipe excess gel off the treatment head with a damp cloth. Disinfect treatment head with antiseptic wipe. Do not immerse treatment head in water or solvent.
10. When power shuts off, leave unit off for 30 minutes before restarting unit.
11. After every treatment, disconnect AC adaptor from power source.
12. Do not impact the treatment head or drop treatment head on the floor.

Technical Specifications:

  • Acoustic Frequency: 1 MHz + 10%, 3MHz + 10%
  • Output Power:
    • 0.5W - 10.0W + 20% when duty factor >80% for 5cm2
    • 0.5W - 15.0W + 20% when duty factor <7-% for 5cm2
    • 0.1W - 2.0W + 20% when duty factor >80% for 1cm2
    • 0.1W - 3.0W + 20% when duty factor <70% for 1 cm2
  • Pulse repetition rate: 100Hz + 10%
  • Duty Factor: 10% - 100%, Stepping 10%
  • Timer: Max 30 Minutes
  • Effective radiating area: 5.0cm2 + 20%; 1.0cm2 + 20%
  • Actual Intensity:
    • 3.0W/cm2 + 20% (1.0MHz)
    • 3.0W/cm2 _20% (3MHz)
  • RBN (Max): 5.0
  • Beam Type: Collimated
  • Material of Applicator: Aluminum
  • Waterproof Grade: IPX7 Only for treatment head

Contraindications:

1. The Sound Care Plus Portable Ultrasound should not be used for the treatment of malignancies nor in the region with malignant tumors.
2.Do not use on people with poor arterial circulation.
3.Do not use over area with bleeding or infections.
4.Do not use over the eyes.
5.Do not use on someone who is pregnant.
6.Do no use for patients with demand type cardiac pacemakers.
7.Do not use over the carotid sinus nerves or arteries and laryngeal or pharyngeal muscles.

Other Information:

DO’S and DON’TS

DO’S
1.Do follow instructions of a licensed practitioner.
2.Do keep the treatment head clean.
3.lnform your clinician if you have any problems or questions
regarding the ultrasound.
4.Do clean cables with water and mild soap. Do not use rubbing alcohol or any other solvent.

DON’TS
1. Do not damage your Portable Ultrasound by bumping, dropping,
or rough use.
2.Do not immerse Portable Ultrasound in water or other solvents.
3.Do not pull or kink cables.
4.Do not store below 32°F (0°C) or over 122°F (50°C).

©2006 OTCWhlesale LLC
www.CurrentSolutionsNow.com

Product Reviews

Directions:

1. Connect power wire to wire socket.
2. Connect AC adaptor to power.
3. Apply sufficient gel to skin at target area.
4. Switch on the power. It power signal light is on, start to use Portable Ultrasound.
5. Place the treatment head on the skin and move it slowly over the target area in a circular motion or in linear strokes at a rate of about 1 inch per second. DO NOT stop moving treatment head while in use.
6. Use special care on bony prominence's to avoid discomfort.
7. The power automatically turns off in 10 minutes or, if desired, the power can be turned off sooner by pushing the ON/OFF switch to OFF.
8. After using the Sound Care Plus, clean skin with water to remove gel.
9. Wipe excess gel off the treatment head with a damp cloth. Disinfect treatment head with antiseptic wipe. Do not immerse treatment head in water or solvent.
10. When power shuts off, leave unit off for 30 minutes before restarting unit.
11. After every treatment, disconnect AC adaptor from power source.
12. Do not impact the treatment head or drop treatment head on the floor.

Contraindications:

1. The Sound Care Plus Portable Ultrasound should not be used for the treatment of malignancies nor in the region with malignant tumors.
2.Do not use on people with poor arterial circulation.
3.Do not use over area with bleeding or infections.
4.Do not use over the eyes.
5.Do not use on someone who is pregnant.
6.Do no use for patients with demand type cardiac pacemakers.
7.Do not use over the carotid sinus nerves or arteries and laryngeal or pharyngeal muscles.

Package Includes:

Technical Specifications:

  • Acoustic Frequency: 1 MHz + 10%, 3MHz + 10%
  • Output Power:
    • 0.5W - 10.0W + 20% when duty factor >80% for 5cm2
    • 0.5W - 15.0W + 20% when duty factor <7-% for 5cm2
    • 0.1W - 2.0W + 20% when duty factor >80% for 1cm2
    • 0.1W - 3.0W + 20% when duty factor <70% for 1 cm2
  • Pulse repetition rate: 100Hz + 10%
  • Duty Factor: 10% - 100%, Stepping 10%
  • Timer: Max 30 Minutes
  • Effective radiating area: 5.0cm2 + 20%; 1.0cm2 + 20%
  • Actual Intensity:
    • 3.0W/cm2 + 20% (1.0MHz)
    • 3.0W/cm2 _20% (3MHz)
  • RBN (Max): 5.0
  • Beam Type: Collimated
  • Material of Applicator: Aluminum
  • Waterproof Grade: IPX7 Only for treatment head

Other Information:

DO’S and DON’TS

DO’S
1.Do follow instructions of a licensed practitioner.
2.Do keep the treatment head clean.
3.lnform your clinician if you have any problems or questions
regarding the ultrasound.
4.Do clean cables with water and mild soap. Do not use rubbing alcohol or any other solvent.

DON’TS
1. Do not damage your Portable Ultrasound by bumping, dropping,
or rough use.
2.Do not immerse Portable Ultrasound in water or other solvents.
3.Do not pull or kink cables.
4.Do not store below 32°F (0°C) or over 122°F (50°C).

YOU MAY ALSO LIKE
Shopper Award
otcwholesale.com has a Shopper Approved rating of 4.8/5 based on 1938 ratings and reviews

Transcutaneous Electrical Nerve Stimulation (TENS)

TENS is a non-invasive, drug free method of controlling pain, which uses tiny electrical impulses sent through the skin to nerves in order to modify your pain perception. In most people it is effective in reducing or eliminating the pain.

Electronic Muscle Stimulation (EMS)

EMS works by sending electronic pulses to the muscle(s). This is achieved by sending low frequency electric pulses through muscle tissue causing them to gently contract. In this way the muscles are passively exercised and blood flow is increased

Galvanic Stimulators

Galvanic Stimulators use direct current, which creates an electrical field over the treated area. The positive pad works like ice, causing reduced circulation to the area under the pad. The negative pad works like heat, causing increased circulation.

Interferential

IF sends small comfortable electrical impulses through your skin to work on deeper tissue stimulation. The sensation works to prevent pain signals from reaching the brain.

Infrared

Infrared Light Therapy help the body by delivering specific light waveforms that increase circulation. Increasing circulation helps promote healing, lessen swelling, and helps in reducing pain.

Ultrasound

Portable Ultrasounds give advanced pain relief using sonic stimulation of soft tissue cells. They generate pulsed, high frequency sound waves, which travel deep into the tissue, generating vasodilation. This helps increase blood flow to the treated area.

Russian

Russian stimulation uses medium frequencies to provide stimulation to muscle groups. This is used to reduce muscle spasms as well as for muscle strengthening. This method was created to produce maximal muscle strengthening effects.

Micro Current

Microcurrent Therapy uses extremely small amounts of electrical current (millionths of an amp) to help relieve pain and heal soft tissues of the body. The electrical current used in Microcurrent Therapy is so small that it is rarely felt.