CLOSE
FREE SHIPPING
ON ORDERS OVER $49*
DOMESTIC, UNDER 10 LBS
Home  >  Electrotherapy  >  TENS Unit Nerve Stimulators  >  Roscoe Medical InTENSity Care-Tec IV Digital Combo TENS, EMS, Interferential and Russian Unit
UPC: 092237613795
Code: koalaty-dt4444

Roscoe Medical InTENSity Care-Tec IV Digital Combo TENS, EMS, Interferential and Russian Unit

Roscoe Medical InTENSity Care-Tec IV Digital Combo TENS, EMS, Interferential and Russian Unit
Click To Enlarge
Save on Wholesale Discount Pricing
You BuyYour PriceYou SaveTotal Cost
3 or more
6 or more
12 or more
$99.73
$94.46
$89.95
$96.26 (49%)
$101.53 (52%)
$106.04 (54%)
$299.19
$566.76
$1,079.40
Retail Price: $195.99
Your price: $104.99
You Save: $91.00 (46%)
Recommended Items
TENS Unit Accessories Kit, Electrode Pads (x8), Wires (x2), Spray, Lotion, Skin Prep & 9V Battery
TENS Unit Accessories Kit, Electrode Pads (x8), Wires (x2), Spray, Lotion, Skin Prep & 9V Battery
Sale Price: $15.95
TENS Unit Electrode Pads, White Cloth Backed, 2 x 2 Square - 16 Pads
TENS Unit Electrode Pads, White Cloth Backed, 2 x 2 Square - 16 Pads
Sale Price: $10.95
Bio-Flex Premium TENS Silver Electrodes 2 x 2 in Square, White Mesh Backed - 16 Pads
Bio-Flex Premium TENS Silver Electrodes 2 x 2 in Square, White Mesh Backed - 16 Pads
Sale Price: $16.95
Cosmetic Bag - Tan Vintage Leather
Cosmetic Bag - Tan Vintage Leather
Our Price: $29.95
Qty:
In Stock
SAME DAY SHIPPING
HASSLE FREE RETURNS
100% SECURE
PRODUCT VIDEO
  • Description
  • Features
  • Uses
  • Warnings
  • Includes
  • Technical
  • Warranty
  • Accessories
  • More
CareTec™IV Dual Channel TENS, EMS, IF, and Russian Stimulator - 1 ea.
Four Modes (TENS/EMS/IF/RUSS) and Fourteen Programs of Electrical Stimulation

The CareTec™IV is an electrotherapy stimulation device that is easily portable and consists of four modes: Transcutaneous Electrical Nerve Stimulation, Electronic Muscle Stimulation, Interferential Stimulation, and Russian Stimulation. All four of these therapeutic modes are able to be used for pain relief and electrical muscle stimulation. The CareTec™IV is dual channel and has a multitude of adjustable settings throughout its' 14 programs. From intensity levels, to time lengths, pulse rates, widths, and amplitudes, and also frequencies there is everything you would need to find the perfect setting that fits according to the needs of the patient.

  • TENS Stimulation
  • EMS Stimulation
  • Interferential Stimulation
  • Russian Stimulation
  • Dual Channel
  • LCD Display
  • 14 Programs

View the full operations manual: pdf manualInTENSity Care-Tec IV Operations Manual

What is TENS?

What is EMS?

What is IF?

What is Russian Stimulation?

Questions: Call Manufacturer at 800-871-7858 or Visit: www.roscoemedical.com

Features:

  • 4 Modes and 14 Programs
    • TENS - 4 Programs
    • EMS - 3 Programs
    • IF - 4 Programs
    • Russian - 3 Programs
  • Channel: Dual, isolated between channels
  • Power Supply: 9.0V DC Battery (Type - 6LR61)
  • Operating Conditions:
    • Temperature: 41°F - 104°F (5°C - 40°C)
    • Relative Humidity: 30% - 75%
    • Atmospheric Pressure: 700 - 1060 Hpa
  • Storage Conditions:
    • Temperature: 14°F - 122°F (-10°C - 50°C)
    • Relative Humidity: 10% - 90%
    • Atmospheric Pressure: 700 - 1060 Hpa
  • Dimensions: 4.5 x 2.55 x 0.9 in. (LxWxH)
  • Weight: 0.28 lbs (With battery)
  • Tolerance:
    • ± 5% on all settings
    • ±10% on output of intensity
  • Timer:
    • Adjustable - from 1 to 60 minutes or Continuous
    • Adjustable in 1 minutes each step
    • Treatment time countdown automatically

Technical Specifications:

  • TRANSCUTANEOUS ELECTRICAL NERVE STIMULATION (TENS)
    • Waveform: Mono-phase square pulse wave
    • Pulse Amplitude: Adjustable, 0 ~ 100mA peak at 100ohm Load each channel; 1mA/step.
    • Pulse Width: Adjustable, from 50 - 300µs, 10µs/step
    • Pulse Rate: Adjustable, from 1 - 150Hz, 1 Hz/step
    • Programs: 4 Programs (Burst, Normal, Pulse Width Modulation, and Pulse Rate Modulation)
  • ELECTRICAL MUSCLE STIMULATION (EMS):
    • Waveform: Mono-phase square pulse wave
    • Pulse Amplitude: Adjustable, 0-100mA peak at 1000 ohm Load each channel, 1 mA/step
    • Pulse Width: Adjustable, from 50 - 300µs, 10 µs/step.
    • Pulse Rate: Adjustable, from 1 - 150Hz, 1 Hz/step
    • Contraction (ON) Time: Adjustable, 1 - 30 seconds; 1 sec./step
    • Relaxation (OFF) Time: Adjustable, 0 - 60 seconds; 1 sec./step
    • Ramp Rime: Adjustable, 1 - 6 seconds; 1 sec./step
    • Programs: 3 Programs (Synchronous, Alternate, and Delay)
  • INTERFERENTIAL STIMULATION (IF):
    • Waveform: Bi-phase square pulse
    • Pulse Amplitude: Adjustable, 0-70mA peak to peak at 1000ohm Load each channel; 1mA/step
    • Pulse Rate:
      • CH1 - Fundamental Frequency: 4000 Hz fixed
      • CH2 - Selectable Frequency: 4001 - 4150 HZ
      • Interference Frequency - 1 to 150 Hz
    • Pulse Width: 125 µs
    • Programs: 4 Programs (Frequency Modulation 1, 2, 3, and 4)
  • RUSSIAN STIMULATION (RUSS):
    • Waveform: Bi-phase square pulse wave
    • Pulse Amplitude: Adjustable, 0-60mA peak at 1000ohm Load each channel; 1.0mA/step
    • Frequency:
      • Carrier Frequency: Fixed at 2500 Hz
      • Burst Frequency: Adjustable, from 20 - 80Hz, 1.0Hz/step
    • Duty Cycle: 50% for Constant (P1) and Modulation (P3) Programs, 10-50% for Modulation (P2) Program
    • Programs: 3 Programs (Constant (P1), Modulation (P2), and Modulation (P3))

Programs:

  • TRANSCUTANEOUS ELECTRICAL NERVE STIMULATION (TENS):
    • P1 - Burst
      • Frequency: Fixed at 100 Hz
      • Burst Rate: Adjustable, 0.5 - 5Hz, 0.1Hz/step
      • Pulse Width: Adjustable, 50 - 300µs
      • Treat Time: 1-60 min, continuous
    • P2 - Normal (Continuous)
      • Pulse Rate: Adjustable, 1 - 150Hz
      • Frequency: 1 - 150Hz
      • Pulse Width: Adjustable, 50 - 300µs
      • Treat Time: 1-60 min, continuous
    • P3 - Pulse Width Modulation
      • Frequency: 1 - 150Hz
      • Pulse Width: 50 - 300µs (varies in a cycle time)
      • Treat Time: 1-60 min, continuous
    • P4 - Frequency Modulation
      • Frequency: 1 - 150Hz
      • Pulse Width: 50 - 300µs
      • Treat Time: 1-60 min, continuous
      • Pulse Rate: Varies in a cycle time
  • ELECTRICAL MUSCLE STIMULATION (EMS):
    • P1 - Synchronous
      • Stimulation on both channels occurs synchronously
      • Frequency: 1 - 150Hz
      • Pulse Width: 50 - 300µs
      • Treat Time: 1-60 min, continuous
    • P2 - Asynchronous (Alternate)
      • Ch2 Stimulation will occur after Ch1 is completed
      • Frequency: 1 - 150Hz
      • Pulse Width: 50 - 300µs
      • Treat Time: 1-60 min, continuous
    • P3 - Delay
      • Ch2 Stimulation will occur after Ch1 is started + delay time
      • Delay Time: Adjustable, from 1 - 10 sec.
      • Frequency: 1 - 150Hz
      • Pulse Width: 50 - 300µs
      • Treat Time: 1-60 min, continuous
  • INTERFERENTIAL STIMULATION (IF):
    • P1 - Frequency Modulation
      • Frequency: 4kHz
        • CH1: Fixed at 4000Hz
        • CH2: 4001-4010Hz varied in a cycle time
      • Pulse Width: 125µs
      • Treat Time: 1-60 min, continuous
      • Cycle Time: Adjustable, 5 - 30 seconds
    • P2 - Frequency Modulation
      • Frequency: 4kHz
        • CH1: Fixed at 4000Hz
        • CH2: 4001-4150Hz varied in a cycle time
      • Pulse Width: 125µs
      • Treat Time: 1-60 min, continuous
      • Cycle Time: Adjustable, 5 - 30 seconds
    • P3 - Frequency Modulation
      • Frequency: 4kHz
        • CH1: Fixed at 4000Hz
        • CH2: 4080-4150Hz varied in a cycle time
      • Pulse Width: 125µs
      • Treat Time: 1-60 min, continuous
    • P4 - Frequency Modulation
      • Frequency: 4kHz
        • CH1: Fixed at 4000Hz
        • CH2: 4001-4150Hz varied in a cycle time
      • Pulse Width: 125µs
      • Treat Time: 1-60 min, continuous
      • Cycle Time: Adjustable, 5 - 30 seconds
  • RUSSIAN STIMULATION (RUSS):
    • P1 - Continuous
      • Burst Frequency: 20 ~ 80Hz
      • Pulse Width: Burst Width 6 ~ 25ms
      • Treat Time: 1-60 min, continuous
      • Duty Cycle: 50%
    • P2 - Modulation
      • Burst Frequency: 20 ~ 80Hz
      • Pulse Width: Burst Width 6 ~ 25ms
      • Treat Time: 1-60 min, continuous
      • Duty Cycle: Varies in a cycle time from 10 - 50%
      • Cycle time: Adjustable 5 - 30 seconds
    • P3 - Modulation
      • Burst Frequency varies in cycle time
      • Burst Frequency: 20 ~ 80Hz
      • Pulse Width: Burst Width 6 ~ 25ms
      • Treat Time: 1-60 min, continuous
      • Duty Cycle: 50%
      • Cycle time: Adjustable 5 - 30 seconds

Uses:

  • Symptomatic relief of chronic intractable pain; post traumatic pain; post surgical pain
  • Relaxation of muscle spasm
  • Increase of blood flow circulation
  • Prevention of disuse atrophy
  • Muscle re-education
  • Maintaining or increasing range of motion
  • Immediate post-surgical stimulation of calf muscles to prevent venous thrombosis

Package Includes:

  • Electrical Stimulator Device
  • 2 x Electrodes Leads
  • 4 x 40x40mm adhesive electrodes
  • 9V Battery (Type 6LR61)
  • Instruction Manual
  • Carrying Case

Warnings:

  1. This device should be used only under the continued supervision of a licensed physician.
  2. The long-term effects of chronic electrical stimulation are unknown. Electrical stimulation devices do not have any curative value.
  3. TENS is a symptomatic treatment and, as such, suppresses the sensation of pain, which would otherwise serve as a protective mechanism.
  4. Safety has not been established for the use of therapeutic electrical stimulation during pregnancy. Do not use during pregnancy unless directed by your physician.
  5. Electrical stimulation is not effective for pain of central origin.
  6. Electronic monitoring equipment (such as ECG monitors and ECG alarms) may not operate properly when electrical stimulation is in use.
  7. Stimulation should not be applied over the carotid sinus nerves, particularly in patients with a known sensitivity to the carotid sinus reflex.
  8. Stimulation should not be applied over the neck or mouth. Severe spasm of the laryngeal and pharyngeal muscles may occur and the contractions may be strong enough to close the airway or cause difficulty in breathing.
  9. Stimulation should not be applied transthoracically in that the introduction of electrical current into the heart may cause cardiac arrhythmias.
  10. Stimulation should not take place while the user is connected to high-frequency surgical equipment, it may cause burn injuries on the skin under the electrodes, as well as problems with the stimulator.
  11. Do not use the stimulator in the vicinity of shortwave or microwave therapy equipment, since this may affect the output power of the stimulator.
  12. Never use in environments with high humidity such as in the bathroom or when having a bath or shower.
  13. Caution should be used in applying electrical stimulation to patients suspected of having heart disease. Further clinical data is needed to show there are no adverse results.
  14. Never use near the heart. Stimulation electrodes should never be placed anywhere on the front of the thorax (marked by ribs and breastbone), but above all not on the two large pectoral muscles. Here it can increase the risk of ventricular fibrillation and lead to cardiac arrest.
  15. Electrodes should not be placed over the eyes, in the mouth, near the genitals or internally.
  16. Never use on the areas of the skin which lack normal sensation
  17. Apply the electrodes to clean, dry, and unbroken skin only.
  18. Keep electrodes separate during treatment, electrodes in contact with other could result in improper stimulation or skin burns.
  19. Keep the stimulator out of reach of children.
  20. Consult your doctor if you are in any doubt whatsoever.

Roscoe Medical
21973 Commerce Parkway
Strongsville, OH 44149
©www.roscoemedical.com

Product Reviews

Features:

  • 4 Modes and 14 Programs
    • TENS - 4 Programs
    • EMS - 3 Programs
    • IF - 4 Programs
    • Russian - 3 Programs
  • Channel: Dual, isolated between channels
  • Power Supply: 9.0V DC Battery (Type - 6LR61)
  • Operating Conditions:
    • Temperature: 41°F - 104°F (5°C - 40°C)
    • Relative Humidity: 30% - 75%
    • Atmospheric Pressure: 700 - 1060 Hpa
  • Storage Conditions:
    • Temperature: 14°F - 122°F (-10°C - 50°C)
    • Relative Humidity: 10% - 90%
    • Atmospheric Pressure: 700 - 1060 Hpa
  • Dimensions: 4.5 x 2.55 x 0.9 in. (LxWxH)
  • Weight: 0.28 lbs (With battery)
  • Tolerance:
    • ± 5% on all settings
    • ±10% on output of intensity
  • Timer:
    • Adjustable - from 1 to 60 minutes or Continuous
    • Adjustable in 1 minutes each step
    • Treatment time countdown automatically

Uses:

  • Symptomatic relief of chronic intractable pain; post traumatic pain; post surgical pain
  • Relaxation of muscle spasm
  • Increase of blood flow circulation
  • Prevention of disuse atrophy
  • Muscle re-education
  • Maintaining or increasing range of motion
  • Immediate post-surgical stimulation of calf muscles to prevent venous thrombosis

Warnings:

  1. This device should be used only under the continued supervision of a licensed physician.
  2. The long-term effects of chronic electrical stimulation are unknown. Electrical stimulation devices do not have any curative value.
  3. TENS is a symptomatic treatment and, as such, suppresses the sensation of pain, which would otherwise serve as a protective mechanism.
  4. Safety has not been established for the use of therapeutic electrical stimulation during pregnancy. Do not use during pregnancy unless directed by your physician.
  5. Electrical stimulation is not effective for pain of central origin.
  6. Electronic monitoring equipment (such as ECG monitors and ECG alarms) may not operate properly when electrical stimulation is in use.
  7. Stimulation should not be applied over the carotid sinus nerves, particularly in patients with a known sensitivity to the carotid sinus reflex.
  8. Stimulation should not be applied over the neck or mouth. Severe spasm of the laryngeal and pharyngeal muscles may occur and the contractions may be strong enough to close the airway or cause difficulty in breathing.
  9. Stimulation should not be applied transthoracically in that the introduction of electrical current into the heart may cause cardiac arrhythmias.
  10. Stimulation should not take place while the user is connected to high-frequency surgical equipment, it may cause burn injuries on the skin under the electrodes, as well as problems with the stimulator.
  11. Do not use the stimulator in the vicinity of shortwave or microwave therapy equipment, since this may affect the output power of the stimulator.
  12. Never use in environments with high humidity such as in the bathroom or when having a bath or shower.
  13. Caution should be used in applying electrical stimulation to patients suspected of having heart disease. Further clinical data is needed to show there are no adverse results.
  14. Never use near the heart. Stimulation electrodes should never be placed anywhere on the front of the thorax (marked by ribs and breastbone), but above all not on the two large pectoral muscles. Here it can increase the risk of ventricular fibrillation and lead to cardiac arrest.
  15. Electrodes should not be placed over the eyes, in the mouth, near the genitals or internally.
  16. Never use on the areas of the skin which lack normal sensation
  17. Apply the electrodes to clean, dry, and unbroken skin only.
  18. Keep electrodes separate during treatment, electrodes in contact with other could result in improper stimulation or skin burns.
  19. Keep the stimulator out of reach of children.
  20. Consult your doctor if you are in any doubt whatsoever.

Package Includes:

  • Electrical Stimulator Device
  • 2 x Electrodes Leads
  • 4 x 40x40mm adhesive electrodes
  • 9V Battery (Type 6LR61)
  • Instruction Manual
  • Carrying Case

Technical Specifications:

  • TRANSCUTANEOUS ELECTRICAL NERVE STIMULATION (TENS)
    • Waveform: Mono-phase square pulse wave
    • Pulse Amplitude: Adjustable, 0 ~ 100mA peak at 100ohm Load each channel; 1mA/step.
    • Pulse Width: Adjustable, from 50 - 300µs, 10µs/step
    • Pulse Rate: Adjustable, from 1 - 150Hz, 1 Hz/step
    • Programs: 4 Programs (Burst, Normal, Pulse Width Modulation, and Pulse Rate Modulation)
  • ELECTRICAL MUSCLE STIMULATION (EMS):
    • Waveform: Mono-phase square pulse wave
    • Pulse Amplitude: Adjustable, 0-100mA peak at 1000 ohm Load each channel, 1 mA/step
    • Pulse Width: Adjustable, from 50 - 300µs, 10 µs/step.
    • Pulse Rate: Adjustable, from 1 - 150Hz, 1 Hz/step
    • Contraction (ON) Time: Adjustable, 1 - 30 seconds; 1 sec./step
    • Relaxation (OFF) Time: Adjustable, 0 - 60 seconds; 1 sec./step
    • Ramp Rime: Adjustable, 1 - 6 seconds; 1 sec./step
    • Programs: 3 Programs (Synchronous, Alternate, and Delay)
  • INTERFERENTIAL STIMULATION (IF):
    • Waveform: Bi-phase square pulse
    • Pulse Amplitude: Adjustable, 0-70mA peak to peak at 1000ohm Load each channel; 1mA/step
    • Pulse Rate:
      • CH1 - Fundamental Frequency: 4000 Hz fixed
      • CH2 - Selectable Frequency: 4001 - 4150 HZ
      • Interference Frequency - 1 to 150 Hz
    • Pulse Width: 125 µs
    • Programs: 4 Programs (Frequency Modulation 1, 2, 3, and 4)
  • RUSSIAN STIMULATION (RUSS):
    • Waveform: Bi-phase square pulse wave
    • Pulse Amplitude: Adjustable, 0-60mA peak at 1000ohm Load each channel; 1.0mA/step
    • Frequency:
      • Carrier Frequency: Fixed at 2500 Hz
      • Burst Frequency: Adjustable, from 20 - 80Hz, 1.0Hz/step
    • Duty Cycle: 50% for Constant (P1) and Modulation (P3) Programs, 10-50% for Modulation (P2) Program
    • Programs: 3 Programs (Constant (P1), Modulation (P2), and Modulation (P3))

Programs:

  • TRANSCUTANEOUS ELECTRICAL NERVE STIMULATION (TENS):
    • P1 - Burst
      • Frequency: Fixed at 100 Hz
      • Burst Rate: Adjustable, 0.5 - 5Hz, 0.1Hz/step
      • Pulse Width: Adjustable, 50 - 300µs
      • Treat Time: 1-60 min, continuous
    • P2 - Normal (Continuous)
      • Pulse Rate: Adjustable, 1 - 150Hz
      • Frequency: 1 - 150Hz
      • Pulse Width: Adjustable, 50 - 300µs
      • Treat Time: 1-60 min, continuous
    • P3 - Pulse Width Modulation
      • Frequency: 1 - 150Hz
      • Pulse Width: 50 - 300µs (varies in a cycle time)
      • Treat Time: 1-60 min, continuous
    • P4 - Frequency Modulation
      • Frequency: 1 - 150Hz
      • Pulse Width: 50 - 300µs
      • Treat Time: 1-60 min, continuous
      • Pulse Rate: Varies in a cycle time
  • ELECTRICAL MUSCLE STIMULATION (EMS):
    • P1 - Synchronous
      • Stimulation on both channels occurs synchronously
      • Frequency: 1 - 150Hz
      • Pulse Width: 50 - 300µs
      • Treat Time: 1-60 min, continuous
    • P2 - Asynchronous (Alternate)
      • Ch2 Stimulation will occur after Ch1 is completed
      • Frequency: 1 - 150Hz
      • Pulse Width: 50 - 300µs
      • Treat Time: 1-60 min, continuous
    • P3 - Delay
      • Ch2 Stimulation will occur after Ch1 is started + delay time
      • Delay Time: Adjustable, from 1 - 10 sec.
      • Frequency: 1 - 150Hz
      • Pulse Width: 50 - 300µs
      • Treat Time: 1-60 min, continuous
  • INTERFERENTIAL STIMULATION (IF):
    • P1 - Frequency Modulation
      • Frequency: 4kHz
        • CH1: Fixed at 4000Hz
        • CH2: 4001-4010Hz varied in a cycle time
      • Pulse Width: 125µs
      • Treat Time: 1-60 min, continuous
      • Cycle Time: Adjustable, 5 - 30 seconds
    • P2 - Frequency Modulation
      • Frequency: 4kHz
        • CH1: Fixed at 4000Hz
        • CH2: 4001-4150Hz varied in a cycle time
      • Pulse Width: 125µs
      • Treat Time: 1-60 min, continuous
      • Cycle Time: Adjustable, 5 - 30 seconds
    • P3 - Frequency Modulation
      • Frequency: 4kHz
        • CH1: Fixed at 4000Hz
        • CH2: 4080-4150Hz varied in a cycle time
      • Pulse Width: 125µs
      • Treat Time: 1-60 min, continuous
    • P4 - Frequency Modulation
      • Frequency: 4kHz
        • CH1: Fixed at 4000Hz
        • CH2: 4001-4150Hz varied in a cycle time
      • Pulse Width: 125µs
      • Treat Time: 1-60 min, continuous
      • Cycle Time: Adjustable, 5 - 30 seconds
  • RUSSIAN STIMULATION (RUSS):
    • P1 - Continuous
      • Burst Frequency: 20 ~ 80Hz
      • Pulse Width: Burst Width 6 ~ 25ms
      • Treat Time: 1-60 min, continuous
      • Duty Cycle: 50%
    • P2 - Modulation
      • Burst Frequency: 20 ~ 80Hz
      • Pulse Width: Burst Width 6 ~ 25ms
      • Treat Time: 1-60 min, continuous
      • Duty Cycle: Varies in a cycle time from 10 - 50%
      • Cycle time: Adjustable 5 - 30 seconds
    • P3 - Modulation
      • Burst Frequency varies in cycle time
      • Burst Frequency: 20 ~ 80Hz
      • Pulse Width: Burst Width 6 ~ 25ms
      • Treat Time: 1-60 min, continuous
      • Duty Cycle: 50%
      • Cycle time: Adjustable 5 - 30 seconds

Warranty:

  1. The warranty period for device is one year from date of purchase. In case of a warranty claim, the date of purchase has to be proven by means of the sales receipt or invoice.
  2. Repairs under warranty do not extend the warranty period either for the device or the replacement parts.
  3. The following is excluded under the warranty:
    1. All damage which has arisen due to improper treatment, e.g. nonobservance of the user instruction.
    2. All damage which is due to repairs or tampering by the customer or unauthorized third parities.
    3. Damage which has arisen during transport from the manufacturer to the consumer or during transport to the service center.
    4. Accessories which are subject to normal wear and tear.
  4. Liability for direct or indirect consequential losses caused by the unit is excluded even if the damage to the unit is accepted as a warranty claim.
TENS Unit Replacement Lead Wires with Pin Connectors, 45 in - 2 ea
Retail Price: $12.99
Your price: $4.95
You Save: $8.04 (62%)
9V Super Heavy Duty Alkaline Battery
Retail Price: $1.99
Your price: $1.49
You Save: $0.50 (25%)
Axelgaard Ultrastim X 2 x 2 in Square - 4 Pads
Retail Price: $9.95
Your price: $4.49
You Save: $5.46 (55%)
Roscoe Medical InTENSity 2 x 2 in Square Electrode
Retail Price: $15.95
Your price: $4.95
You Save: $11.00 (69%)
Premium TENS Silver Electrode 4 x 6 in Butterfly, Blue Mesh Backed - 1 Pad
Retail Price: $8.99
Your price: $4.95
You Save: $4.04 (45%)
TENS Unit Low Back Electrode Strip White Foam Backed 1.5 x 13 in strip - 1 Pad
Retail Price: $18.99
Your price: $6.49
You Save: $12.50 (66%)
Roscoe Medical TENS Electrodes 2 x 2 in Square, Tan Mesh Backed - 4 Pads
Retail Price: $8.99
Your price: $3.95
You Save: $5.04 (56%)
YOU MAY ALSO LIKE
Shopper Award
otcwholesale.com has a Shopper Approved rating of 4.8/5 based on 1938 ratings and reviews

Transcutaneous Electrical Nerve Stimulation (TENS)

TENS is a non-invasive, drug free method of controlling pain, which uses tiny electrical impulses sent through the skin to nerves in order to modify your pain perception. In most people it is effective in reducing or eliminating the pain.

Electronic Muscle Stimulation (EMS)

EMS works by sending electronic pulses to the muscle(s). This is achieved by sending low frequency electric pulses through muscle tissue causing them to gently contract. In this way the muscles are passively exercised and blood flow is increased

Galvanic Stimulators

Galvanic Stimulators use direct current, which creates an electrical field over the treated area. The positive pad works like ice, causing reduced circulation to the area under the pad. The negative pad works like heat, causing increased circulation.

Interferential

IF sends small comfortable electrical impulses through your skin to work on deeper tissue stimulation. The sensation works to prevent pain signals from reaching the brain.

Infrared

Infrared Light Therapy help the body by delivering specific light waveforms that increase circulation. Increasing circulation helps promote healing, lessen swelling, and helps in reducing pain.

Ultrasound

Portable Ultrasounds give advanced pain relief using sonic stimulation of soft tissue cells. They generate pulsed, high frequency sound waves, which travel deep into the tissue, generating vasodilation. This helps increase blood flow to the treated area.

Russian

Russian stimulation uses medium frequencies to provide stimulation to muscle groups. This is used to reduce muscle spasms as well as for muscle strengthening. This method was created to produce maximal muscle strengthening effects.

Micro Current

Microcurrent Therapy uses extremely small amounts of electrical current (millionths of an amp) to help relieve pain and heal soft tissues of the body. The electrical current used in Microcurrent Therapy is so small that it is rarely felt.